NanoDrop Ultra
Next Generation microvolume spectrophotometer with advanced contaminant detection capabilities, DNA/RNA differentiation and microvolume fluorescence option
All-In-One Microvolume Absorbance and Fluorescence
Unique on-pedestal microvolume fluorescence quantification on Ultra FL and CFL versions. Blue (470 nm) and Red (630 nm) excitation LEDs. Pre-programmed applications for the NanoDrop Ultra quantification kits, or use your own assays with fluorometer mode
User Friendly Design
High resolution 10.1 inch touchscreen interface with tilt adjustment. USBC power connection allows operation using an external battery pack. Auto blank and measure features streamline workflow
Acclaro Sample Intelligence
Identifies and corrects for contaminants (including DNA/RNA differentiation for mammalian, plant or bacterial samples), monitors sample column for bubbles and provides feedback about sample quality with guided troubleshooting
Acclaro Pro for PAT
Optional Acclaro Pro software upgrade uses optimised calibration and software algorithms to provide enhanced accuracy for Process Analytical Technology environments (e.g antibody or oligo production)
Versatile Data Management
Front mounted USB-C port, rear USB-A, ethernet and WIFI. Seamless data export into Google Drive or Microsoft OneDrive. Data export preview feature allows you to tailor report format to meet your needs for printing or saving as a pdf. RESTful API for streamlined LIMS export compatibility
qPCR Recipe Calculator
Fully integrated qPCR recipe calculator – use the built-in library of kits, or add your favourite, to let the software run the calculations for you. The qPCR recipe calculator suggests how to prepare the reaction based on your sample’s concentration
Compliant
Optional SciVault 2 software enables 21 CFR part 11 compliance for regulated environments. Choice of configurations (instrument, connected PC or remote PC)
Minimal Sample Preparation
Powerful auto-range pathlength technology ensures accurate measurements for even highly concentrated samples without the need for dilutions. No prior knowledge of sample concentration required
£0.00
- Specifications
- Nucleic Acids
- Proteins and Peptides
- Design and Operation
- Data Exporting
- Other Applications
- Fluorescence + Acclaro Pro
- Request Demo
Instrument Control – Built-in 10.1 inch touchscreen or PC control
Minimum Sample Volume – 1 µL
Limit of Detection – dsDNA Pedestal: 1.0 ng/µL
BSA (IgG) Pedestal: 0.03 (0.032) mg/mL
Maximum Concentration – dsDNA Pedestal: 27,500 ng/µL
BSA (IgG) Pedestal: 820 (400) mg/mL
Photometric Range – 0.02 – 550 Abs (10 mm equivalent)
Photometric Accuracy – 3% at 0.97A, 302 nm
Pathlengths – 1.0, 0.2, 0.1, 0.05 and 0.03 mm auto-ranging
Measurement and Data Processing Time – 7 seconds
Wavelength Range – 190-850 nm
Dimensions (W × D × H) – 32 × 18 × 28 cm (12.6 × 7.1 × 11.0 in.)
Weight – 4.1 kg (9.0 lbs.)
Internal Storage – 64 GB (~500,000 samples)
On-board Control – Custom Linux with 1.6 GHz Quad Core CPU
Power Consumption – 7 W at idle, 11-18 W at Working Conditions
Battery – Supports a USBC external battery pack (75 Wh yields ~8 hours of runtime)
Connectivity – 2 x USB-A ports, 2 x USB-C, Ethernet, Bluetooth® and WiFi
Warranty – 2 Years
Fluorescence Minimum Sample Volume – 2 µL
Fluorescence LEDs – Blue (max ~470 nm) and Red (max ~ 635 nm)
Detector – 2048 element CMOS linear image sensor
- Simple operation – Pipette, Measure and Clean
- No specialist consumables required
- Wide dynamic range 1 – 27,500 ng/ul ds DNA means no requirement for dilutions.
- The maximum concentration is ~8 fold higher than on the ND1000
- 5 Auto-ranging pathlengths ensure accurate data across the whole concentration range with no prior knowledge of sample concentration required
- Automatic calculation of sample concentration, A260/A280 and A260/A230 Purity ratios
- Dedicated Oligo calculation software module
- qPCR recipe calculator
- Microarray module for labelling efficiency determination
- Acclaro Sample Intelligence Technology
- Identification of key contaminants such as protein, guanidine salts and phenol, with corrected concentration
- Differentiation between DNA and RNA (mammalian, plant or bacterial) and correction for RNA contamination in dsDNA samples and vice versa
- Information alerts for abnormal purity ratios and issues with the blank with
- Digital image processing alerts to bubbles and anomalies with the sample that can affect measurement integrity
- On-board guided troubleshooting and learning
- Simple operation – Pipette, Measure, Clean, as with the ND1000.
- No specialist consumables required
- Wide dynamic range 0.06- 820 mg/ml BSA means no requirement for dilutions.
- The maximum concentration is ~8 fold higher than on the ND1000
- 5 Auto-ranging pathlengths ensure accurate data across the whole concentration range no prior knowledge of sample concentration required
- Automatic calculation of sample concentration, A260/A280 and Purity ratio
- Protein Editor allows input/saving of user-defined protein information
- Dedicated A205 module for quantification of peptides and proteins lacking tryptophan or tyrosine residues
- A UV Vis Spectrophotometer with native low stray light and deep UV detection
- Proteins and Labels Module for labelling efficiency determination
- Pre-configured modules for colorimetric protein assays including Bradford, BCA, Lowry and Pierce 660
- Acclaro™ Sample Intelligence Technology
- Identification of key contaminants with corrected concentration
- Information alerts for abnormal purity ratios and issues with the blank
- Digital image processing alerts to bubbles and anomalies with the sample that can affect measurement integrity
- On-board guided troubleshooting and learning
· Choice of standalone operation or PC control
· 21 CFR part 11 compliance with optional SciVault 2 software which can be installed on the instrument itself for local control or onto a directly connected or networked PC
· Auto blank and auto measure features streamline your workflow
· Large 10.1 inch high resolution glove compatible touchscreen interface with tilt adjustment to ensure ergonomic operation
· LED light bar provides current instrument status
· Front USBC port for data transfer via USBC flash drives (USBA/C dual drive included)
· Rear USBA port for peripheral connectivity or data export and USBB for PC connection
· Bluetooth connectivity for external keyboard or mouse
· Wifi and Ethernet connectivity
· Multi-language support
- Real-time saving of results (up to 500,000 on the internal storage)
- Export in a range of formats including .csv and .tsv
- Export of data via USB flash drive, Ethernet or Wi-Fi
- Front mounted USBC port for convenient export
- Cloud connectivity for seamless data export into Google Drive or Microsoft Onedrive
- RESTful API provides LIMS compatibility
- Intuitive search functionality with User Identifiers / Tags
- Report preview function allows you to customise your export format to meet downstream requirements
- Connect a Dymo Labelwriter for lab notebook friendly adhesive label printouts
- Printing of spectral data or reports to Wi-Fi network printers or USB connected printers
- Full audit trail capability provided by optional 21 CFR part 11 compliant SciVault 2 software
- PC control via USB connection and free of charge PC control software if required
- Full wavelength scans from 190-850 nm using the UV-Vis module
- OD 600 measurements with cell number conversion option
- Create your own Custom Methods on the instrument itself
- Download and install pre-configured methods
Fluorescence
- Blue and Red solid state LEDs provide on-pedestal microvolume fluorescent quantification
- Pre configured modules for use with the NanoDrop Ultra quantification kits
- Fluorometer mode allows you to use your preferred quantification kit
Acclaro Pro
- Additional software and factory calibration provide accurate high concentration measurements within 5% error up to 550 Abs (10mm equivalent) – up to 400 mg/ml IgG
- Take triplicate measurements on the pedestal in under 2 minutes